[Input terminal function setting (2/2)] Sensorless vector/vector with sensor (: valid, -: invalid)
Positive
logic
Negative
logic
Function
Speed
control
Torq ue
control
PM control V/f EOQF= H= Reference
70 71 Servo lock signal / - -
72 73 Simple positioning (positioning loop) / - -
74 75 Integrating wattmeter display clear / - -
76 77 Trace back trigger signal / - -
78 79 Light-load high-speed operation prohibitive signal / - ●●●-
86 87 Binary data write /●●/●● -
88 89 Up/Down frequency (up)*1 / - ●●●-
90 91 Up/Down frequency (down)*1 / - ●●●-
92 93 Up/Down frequency (clear) / - ●●●-
98 99 Forward/reverse selection /●●/●● -
100 101 Run/Stop command /●●/●● -
102 103 Commercial power/INV switching / - ●●●-
104 105 Frequency reference priority switching / - ●●●-
106 107 VI/II terminal priority / - ●●●-
108 109 Command terminal board priority /●●/●● -
110 111 Parameter editing enabling /●●/●● -
112 113 Control switching (torque/position) /●●/ --*2-
122 123 Rapidest deceleration command / - -
124 125 Preliminary excitation /●●/●● -
126 127 Braking request / - ●●●-
130 131 Brake answer back input / - ●●●-
134 135 Traverse permission signal / - -
7.2.1
*1: The deceleration/deceleration time depends on the CEE/FGE setting, unless switching between acceleration and deceleration is performed.
*2: Dependent on EOQF.