K-23
E6581301
11
[24] Protection functions [2/3]
Vector control
Title
Communi
cation
No.
Function Adjustment range
Minimum
settin
unit
Panel/Communi
cation)
Default
settin
Write durin
runnin
Speed
control
Torq ue
control
PM
control
V/f Constan
Reference
H 0613
Selection of short circuit
detection at starting
0:Each time (standard pulse)
1:Only one time after power is turned on
2:Each time (short pulse)
3.Onl
one time after power is turn on
short pulse
1/1 0 Disabled ●/●●/●●●6. 33. 9
H 0615 Overtorque trip selection 0:No trip, 1:Trip 1/1 0 Enabled ●/●●/●●●6. 33. 10
H 0616
Overtorque detection level
during power running
0~250% 1/0.01 150 Enabled ●/●●/●●●6. 33. 10
H 0617
Overtorque detection level
during regenerative braking
0~250% 1/0.01 150 Enabled ●/●●/●●●6. 33. 10
H 0618 Overtorque detection time 0.00~10.00 sec. 0.01/0.01 0.50 Enabled ●/●●/●●●6. 33. 10
H 0619 Overtorque detection h
steresis 0~100% 1/0.01 10 Enabled ●/●●/●●●6. 33. 10
H 0620 Cooling fan control selection 0:Auto, 1:Always ON 1/1 0 Enabled ●/●●/●●●6. 33. 11
H 0621
Cumulative operation time alarm
setting
0.1~999.9 (x100h) 0.1/0.1 610.0 Enabled ●/●●/●●●6. 33. 12
H 0622 Abnormal speed detection time 0.01~100.0 sec. 0.01/0.01 0.01 Enabled -/● -/- - - 6. 33. 13
H 0623
Overspeed detection frequency
upper band
0.0:Disabled, 0.1~30.0Hz 0.1/0.01 0.0 Enabled -/● -/- - - 6. 33. 13
H 0624
Overspeed detection frequency
lower band
0.0:Disabled, 0.1~30.0Hz 0.1/0.01 0.0 Enabled -/● -/- - - 6. 33. 13
H 0625 Undervoltage detection level 50~79%, 80: (auto mode)
1/1
80 Disabled ●/●●/●●●6. 33. 15
H 0626 Overvolta
e limit operation level 100~150%
1/1
134 Disabled ●/● - ●●6. 14. 2
H 0627 Undervoltage trip selection 0:Deselect, 1:Select 1/1 0 Disabled ●/●●/●●●6. 33. 15
H 0628
Undervoltage (trip alarm)
detection time
0.01~10.00 sec. 0.01/0.01 0.03 Disabled ●/●●/●●●6. 33. 15
H 0629
Regenerative power ride-through
control
level
55~100% 1/1 75 Disabled ●/●●/●●●6. 33. 16
H 0630 Braking answer waiting time 0.0:Disabled, 0.1~10.0 sec. 0.1/0.1 0.0 Enabled ●/●●/●●●6. 33. 17
H 0631 Inverter overload selection
0:Standard (150%-60 sec.)
1:Estimation of temperature
1/1 0 Disabled - - - - 5. 14
H 0633
VI/II analog input wire breakage
detection level
0:None
1~100%
1/1 0 Enabled ●/●●/●●●6. 33. 18
H 0634
Annual average ambient
temperature
calculation for part
replacement alarms)
1:-10~+10°C
2:+11~+20°C
3:+21~+30°C
4:+31~+40°C
5:+41~+50°C
6:+51~+60°C
1/1 3 Enabled ●/●●/●●●6. 33. 19
H 0635
Rush current suppression relay
activation time
0.0~2.5 sec. 0.1/0.1 0.0 Disabled ●/●●/●●●6. 33. 20
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)