Toshiba Tosvert VF-AS1 Bedienungsanleitung Seite 251

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 312
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 250
K-13
E6581301
11
[14] Functions for lift [1/2]
Vector control
Title
Communi
cation
No.
Function Adjustment range
Minimum
settin
g
unit
(
Panel/Communi
cation)
Default
settin
g
Write durin
g
runnin
g
Speed
control
Torq ue
control
PM
control
V/f Reference
H 0324 Drooping output filter 0.1~200.0 rad/s (Enabled if RV=3, 4, 7 or 8) 0.1/0.1 100.0 Enabled / ---6. 15
H 0328
Li
g
ht-load hi
g
h-speed operation
selection
0:Deselect
1:High-speed operation speed set automatically
(Power running at F command: Increase)
2:High-speed operation speed set automatically
(Power running at R command: Increase)
3:High-speed operation speed set with H
(Power running at F command: Increase)
4:High-speed operation speed set with H
(Power running at R command: Increase)
1/1 0 Enabled / - ●● *1
H 0329
Li
g
ht-load hi
g
h-speed learnin
g
function
0:No learning, 1:Forward run learning
2:Reverse run learning
1/1 0 Disabled / ---*1
H 0330
Automatic light-load high-speed
operation frequency
30.0~WN Hz 0.1/0.01 *2 Disabled / - ●● *1
H 0331
Li
g
ht-load hi
g
h-speed operation
switchin
g
lower limit frequenc
y
30.0~WN Hz 0.1/0.01 40.0 Enabled / - ●● *1
H 0332
Li
g
ht-load hi
g
h-speed operation
load waiting time
0.0~10.0 sec. 0.1/0.1 0.5 Enabled / - ●● *1
H 0333
Li
g
ht-load hi
g
h-speed operation
load detection time
0.0~10.0 sec. 0.1/0.1 1.0 Enabled / - ●● *1
H 0334
Li
g
ht-load hi
g
h-speed operation
heavy load detection time
0.0~10.0 sec. 0.1/0.1 0.5 Enabled / - ●● *1
H 0335
Switching load torque during
power running
-250~250% 1/0.01 50 Enabled / - ●● *1
H 0336
Heav
y
-load torque durin
g
power runnin
g
-250~250% 1/0.01 100 Enabled / - ●● *1
H 0337
Heavy-load torque during
constant power running
-250~250% 1/0.01 50 Enabled / - ●● *1
H 0338
Switching load torque during
regenerative braking
-250~250% 1/0.01 50 Enabled / - ●● *1
H 0341 Braking mode selection
0:Deselect, 1:Forward winding up
2:Reverse winding up
3:Horizontal operation (counter weight)
1/1 0 Enabled / ---6. 17
H 0342
Load portion torque input selection
0:Disabled, 1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:Henabled
5:2-wire RS485 communication input
6:4-wire RS485 communication input
7:Communications option input enabled
8:Optional AI1 (differential current input)
1/1 0 Enabled / ---6. 17
H 0343
Hoisting torque bias input (valid
only when H=)
-250~250% 1/0.01 100 Enabled / ---6. 17
H 0344 Lowerin
g
torque bias multiplie
r
0~100% 1/0.01 100 Enabled / ---6. 17
H 0345 Brake release time 0.00~2.50 sec. 0.01/0.01 0.05 Enabled / ---6. 17
H 0346 Creeping frequency H~20.0 Hz 0.1/0.01 3.0 Enabled / ---6. 17
H 0347 Creeping time 0.0~2.50 sec. 0.01/0.01 0.10 Disabled / ---6. 17
H 0348 Brakin
g
time learnin
g
function 0:Deselect, 1: Learning (0 after adjustment) 1/1 0 Enabled / ---6. 17
*1: For details, refer to Instruction Manual (E6581327) specified in Section 6.41. *2: Inverter with a model number ending with -WN: 60.0 -WP: 50.0
Sensorless vector/vector with sensor (:Effective, -:Ineffective)