U r.
RH
(AM/FM Adjustment Parameters)
FRSL.
RR5L
FR
HR
Meter adjustment parameters
Related parameters
FP5L
FM terminal function selection
RP5L
FP
Frequency meter adjustment
RP
AM terminal function selection
Current meter adjustment
A frequency meter or current meter can be connected to the unit and configured according to the
and
FHSL
RP5L settings,
* The output signal from the FM (AM) terminal is a 0-1 mAdc, 0-7.5Vdc analog signal.
Use a 1 mAdc full-scale ammeter or 7.5Vdc-1 mA full-scale voltmeter.
The meter’s zero point should be adjusted with the meter’s adjusting screw. Calibrate the scale with | F O
or
RP
★ The max. scale of the ammeter should be at least 2.5 times the inverter’s rated output current.
F P5L setting value
RP5L
Function
Default gain
(full-scale level)
0
Pre-compensation reference frequency
FH
1
Post-compensation output frequency
FH
S
Frequency setting value
F H
3
Output current
130%
H
DC voltage Note)
260V (400V class is 520V)
5
Output voltage
260V (400V class is 520V)
B
Torque current
130%
n
Excitation current
130%
B
PID feedback value
FH
g
Motor overload ratio
100%
ID
Inverter overload ratio
100%
/ I
DBR overload ratio
100%
13
Input power
130% of (V^ X 200 or
400V X rated current)
¡3
Output power
130%of(VsT X 200 or
400V X rated current)
Note) If FP5L (or RP5L
) is set to 4 (DC voltage), a DC voltage that is less than approx. 50%
of the rated voltage cannot be measured. Also, if main circuit power is OFF {PDF F displayed), an
approx. 50% bias amount will be constantly output.
- 89 -