
7.4.4 Parameter Setting Function f I P /7 0 d I in Cn.Ut I
Parameters can be set in the standard mode, but alternatively, the panel operation mode selection
(I Pn Od I in C r-.U fc ) can be changed as follows.
PnOdsetting
Function
0
Prohibit all key operations
+ 1
Can perform reset
+ 2
Can perform monitor operations
+ H
Can perform emergency stop
+ B
Can perform run/stop operations
+ IE
Can perform parameter read operations
+ 33 Can perform parameter change operations
E3
Standard mode (all operations valid)
* If I P n 0 d\ is set to 3 , I (reset operations) and 3 (monitor operations) will be valid.
41
Kommentare zu diesen Handbüchern