industrial Application Parameters (Conveyor)
When C^JDfc RPL is set to 3. , G--P , G^F3 . G--Pt . G^G!3 and GrJUt will be
available in settings monitor mode, and the initial setting values will change to those for a conveyor
application.
Group
Function
Title
AdjustmefTt range
Resolution Default
Re
marks
r-
Conveyor
Input terminal selection
it i
1
_ . _ 1
0: Standard terminal functions
1; Individual selection
0
Gr.St
1 ~~r
1 1 Input terminal 0 (R)
IC LJ
1
m
0~51
0: R 0
! Input terminal 1 (SI)
!fc !
1
*
1: SI
1
} Input terminal 2 (S2)
I
1
2; S2
2
\ Input terminal 3 (S3)
¡h3
1
1
3: S3
3
\ Input terminal 4 (S4)
1
1
*
4: S4
4
1 Input terminal 5 (F)
!tS
1
i
Terminal No.
5: F
5
j Input terminal 6 (RES)
Its
1
1
1
«
: terminsil symbol '
6; RES 6
1 Input terminal 7 (ST)
1
1
7: ST
7
I Input terminal 8 (S5)
its
1
»
8: S5 8
I Input terminal 9 (S6)
its
j
9: S6 9
1 Input terminal 10 (S7)
■u
tC
1
10: S7 10
j Input terminal 11 (potential
•u • >
•c • •
1
1
* 11: Potential
33
1 terminal)
1
1
1
1
terminal
Output terminal 0 (RCH) function
selection
Ol O
ulC KJ
"1
1
1
1
0~61
6
Gr.St
Output terminai 1 (LOW) function
selection
Ofc i
1
1
1
4
Output terminal 2 (FL) function
selection
Sts
1
1
1
I
10
Low speed signal output frequency LF :
1
0~maximum frequency 0.1/0.01 Hz 0.5
Gr.St
Start-up frequency F-Sh 1
j
0.0~10
0.1/0.01 Hz 0.5 Gr.SC
End frequency
F-£m i
__
_
_
_
1
_
0.0-30
0.1/0.01 Hz
0.5
Gr.SC
Frequency priority selection #1
FC !
—r~
1
t
1
1
1; RR
2: IV
3: RX
4: PG (pulse input setting)
1
Gr.SF
1
5: BIN (binary or up/down key setting)
Frequency priority selection #2
Fca :
_______
1_
Same as above 3
Gr.SF
RR input selection
i-r- ¡m
1
0: Standard 0
Gr.SF
1
1; Adjustable
1
1 j RR reference point #1
9 i
1
1
m
0-100
1%
0
¡RR point #1 frequency
9-9 !
i
.
0—maximum frequency 0.1/0.01 Hz 0.0
1 RR reference point #2
9S
1
0-100
1%
100
j RR point #2 frequency
i
9-9S
1
1
0—maximum frequency 0.1/0.01 Hz 80.0
RX input selection
<-£ ¡o
1
0: Standard
_
0
Gr.SF
1
+
1: Adjustable
1
1 |RX reference point #1
PS
-100-100
1%
0
j RX point #1 frequency
F-PS
-Maximum frequency— 0.1/0.02 Hz
0.0
t
maximum frequency
1 RX reference point #2
PS
*
-100-100
1%
100
j RX point #2 frequency
F-PS
-Maximum frequency—
0.1/0.02 Hz 80.0
1
»
maximum frequency
Preset speed selection
Sr .o
4.
0: disabled 1—15: speeds (1—15)
0
Gr.SF
Other j Mode selection
Sr r.
«
0: deactivated
_
0
than 1
0 1
____
1
_________________
L.
1: activated
-131 -